To install your Honeywell 951WG recessed contact, you must first drill a hole with a 3/8” diameter into your door or window frame. 3/8" Door Contacts with Magnet. After installing the recessed contact, you must also install the corresponding magnet. I replaced my back door and now my panel is reading a trouble light even though I have the wires tied together with wire nuts so it will still let me know if other doors are opened. Operate Gap ¾" (19mm) min. Now, when your door or window is closed, the magnet will be in close proximity to the contact and the alarm control panel will be happy. View Details. HOME / Hardwired Sensors Detectors / Hard Wired Door Window Contacts / Recessed Door Window Contacts Switches. The AMS-21 Series may be used to secure a variety of openings such as: man doors, sliding doors, windows, and other openings where a concealed contact is necessary. Yes, this sensor should work with any wired alarm system. The AMS-17 Series Mini Recessed Contact is a UL listed contact designed to provide a clean and easy installation for standard openings. You will need to drill a 3/8’ diameter hole in your door or window. Quick View; Newsletter Sign Up. form initial contact contact switching switching resistanceratingvoltagecurrent (Ω) (w)(a) (vdc) Next, you will have to run a (2) conductor alarm wire from your alarm control panel to the hole you just drilled. Recessed Steel Door Contact with Terminals $ 7.99 Add to cart. 3/8" Día with Terminal (for hardwired security systems) Easy & Quick installation. 99 To install your Honeywell 951WG recessed contact, you must first drill a hole with a 3/8” diameter into your door or window frame. I suspect I just wire the 2 leads to the loop terminals in the 5816. The Honeywell 951WG is a miniature recessed contact with 12” wire leads. The unique Magnasphere BMS switch utilized in these devices renders the MSS products virtually unbreakable, and highly resistant to permanent contact welding and outsider magnet defeat. These contacts may be used to secure a … Resistors and Diodes Upon Request Supervisory Loops Available Upon Request Interlogix 2757-L High Security Contacts, Triple Biased, SPDT, … How Do I Install a Honeywell 951WG in a Door. Click to review each patent at the USPTO Patent Full-Text and Image Database. 3/8 inch Mini Recessed Contact. © 2021 MAGNASPHERE Corp. | All Rights Reserved, Wiring schematics for the following part numbers are available on the, MSS 'Standard' Series | UL SECURITY LISTED, No. r 10/07/2013 contact your g.r.i. 3/8 Door Contacts with MagnetWorks for all alarm systems that have hardwired zones3/4 gap closed loop magnetic contact that features a terminal block style connection for accepting wireHave 18 Wire LeadsPress fit design makes installation easy This 3/8 inch recessed contact is nice for those want a concealed contact. Will this work with a dsc alarm panel? You can use the 951WG recessed contact to protect doors and wind... Rare Earth Magnet 3/8" Diameter, 1/8" Long. The 3/8" Hardwired Recessed Contact with Leads is a contact 3/8" in diameter and has 18" leads. Security Store,GE,Window Bars | Burglar Alarms, DSC, Honeywell, Ademco Dirección: youralarmstore.com Descripción: DIY Security Alarm Systems,Home and Business Security Store - Burglar Alarms, Wireless Security, Surveillance Cameras.Window Security Bars, Door … As the included magnet is only 3/4” long, the 951WG is ideal for windows and doors that have a thinner frame such as casement windows and sliding windows. Longer Length. You have been registered for product and offer updates. Recessed Steel Door Contact w/Wire Leads, 3/4" Diameter, Higher Security, Biased for Higher Security Applications, Single Pole-Double Throw, White 1078/1076 Series 1076CW-M Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. However, the 951WG miniature recessed contact has a wide magnet gap of 1.25” so that you can use it with doors and windows that don’t close as tightly. Drill it directly across from your recessed door and … 3/4" gap closed loop magnetic contact that features a terminal block style connection … x 20 mm L] Max Gap: 1/2″ [12.7 mm] Colors: Brown, Grey and White: Electrical Specifications: Max Current: 0.25A Resistive Max Voltage: 30 VDC Max Power: .25 W Resistive Configuration: “Open Loop or Closed Loop w/ Target Magnet in Place: Screw Terminals You can order the miniature recessed contact in your choice of white (951WG-WH) or brown (951WG-BR). Feed the wire through the hole and splice the connection to the 12” zip cord that houses the (2) wire leads coming out the backside of the 951WG recessed contact. The MAGNASPHERE MSS line of security sensors provides a solution to all of the weaknesses and flaws of the reed switch contacts. MAGNASPHERE products are covered by U.S. and International Patents. Press the 951WG into the hole until it is flush with the door or window frame. The MSS Series is UL, ULC listed and CE certified. 20/Pk White 3/8" Recessed Wired Door Window Sensor Alarm Switch Contact Terminal. 2020-12/2020-T SERIES 3/8” Diameter recesseD switch set Recessed Magnetic Contacts Press To Fit 12” Leads #22 AWG Leads or Screw Terminals Longer Leads, Zip Cord or Jacketed Cable Upon Request Hermetically Sealed Plated Contacts Resist Sticking or Freezing Built-in E.O.L. Buy now and save. Add to wishlist. If someone opens the door or window while your security system is armed, an alarm will be triggered. WBOX 0E-DC1651W10 3/8" Recessed Stubby Press Fit Magnetic … Therefore, you will need to drill a matching hole directly opposite the contact. However, if you have the wires twisted together, that should simulate the door being closed so your trouble may be something else or you may have issues with the wiring for the zone. Find many great new & used options and get the best deals for ADEMCO Mps-10a When the magnet is next to the switch, The Loop is Closed. The switch side is 1.25" long and the magnet side is .625" long. Press the magnet into the hole and your installation is complete. What do the different Supervision options mean when programming this sensor as a hardwired connection? Price $8.95. What Is the Best Wired Security Door/Window Contact? $2.10 Only. x 3/4″ L [10 mm Dia. Recessed Door Window ... TANE STB38TCDMBR 3/8" Recessed Brown Contact With Rare Earth Magnet. VIP Contacts are Closed Loop with magnet present and come in white or brown typically. It is good for pre-wiring homes, typically used on doors. The AMS-17 Series is ideal for areas where small size is important. 3/8″ Dia. distributor or call: part loop electrical reed maximum maximum maximum maximum number type config. Grainger's got your back. 5977873, RE39731, 6506987, 6303845, 6603378, and Patents Pending, Available with EOL Resisters Contact Factory. Will the 951WG recessed contact work with an Ademco Vista 4120XM security system? Features Colors: White, Brown Available in closed loop UL and ULC approved Shorter length case Softer fill to protect fragile reed Both are 3/8" in diameter. I believe there was Supervision: Normal Open, Normal Closed, or End of Line. Works for all alarm systems that have hardwired zones. When the magnet is pulled away the loop opens. Hard Wired Door Window Contacts. TANE 34TCWH 3/4" White Contact. Next, you will have to run a (2) conductor alarm wire from your alarm control panel to the hole you just … White & Brown 3/8" Recessed Wired Door Window Alarm Contact Terminal (10/20/50 Pack) 3/8" Door Contacts with Magnet Works for all alarm systems that have hardwired zones 3/4" gap closed loop magnetic contact that features a terminal block style connection for accepting wire Looking for GRAINGER APPROVED 7/16 in" x 9/16 in" x 3/8 in" ABS Plastic Recessed Mount Magnetic Contact (2EXU9)? TANE Recessed alarm contacts are available in diameters ranging from .25”(6.4mm) to 1”(25mm), in Closed Loop, Open Loop, SPDT and DPDT configurations, with wire leads or terminal-connections.