PIs, Lab and Shop Managers) are responsible for initial and annual refresher training of all their workers in A. the eyes or body] potential exists, there must be an emergency eye wash facility that meets ANSI standards.” The U.S. Navy and U.S. Air Force also require the use of ANSI/ISEA Z358.1. – For showers, push valve actuator back. 5. The station should be within 10 seconds travel time, or 50 feet from where you use chemicals. • Personal Wash Units/Bottled Eyewash– o Considered supplemental equipment only o Not an alternative for a 15-minute flushing station. o They do not meet ANSI's requirements for Eyewash and/or Drench Shower stations and should not be used as an alternative to a15-minute flushing station. Fendall Pure Flow 1000 - Part Numbers and Replacement Parts Listing. Year: 1. learn more Halo Configurator Free Safety Site Survey How to Use an Eyewash Station.pdf - Google Docs ... Loading… Emergency Eye Wash & Deluge Showers Let's hope you never need one, but if you do let's hope it's clean and accessible. %PDF-1.7
the eyewash unit at 206.8 Kpa (30 psi). <>/Metadata 419 0 R/ViewerPreferences 420 0 R>>
Get help walking to the eyewash station from a coworker. Most eyewash stations are directly connected to the water system in the workplace. Compliance and conformity to … If corrosive chemicals are present in your workplace, you definitely … 0000033053 00000 n
4 0 obj
stream
Q: What temperature does the standard recommend for eyewash station fluid? SHOWERS Plumbed Shower: An emergency shower permanently connected to a source of potable water Self‐Contained Shower: A shower that contains its own flushing fluid, and must be refilled or replaced after use 1) Heads A. How to Use an Eyewash Station "When a chemical or irritant enters your eyes, knowing how to properly flush them can save your sight." 0000001280 00000 n
0000003262 00000 n
Keep a clear pathway and ensure the station’s frequently inspected and ALWAYS accessible and clean. 3. It should provide a gentle non-injurious flow. B. Spray pattern will have a minimum diameter of 20" at 60" above the floor. Weekly Eyewash Inspection Log Location Year: 2021 Instructions: Activate emergency eyewash to ensure proper operation. x�b```"V�hAd`B�N� �e��E\=~-�m�h���x]g:��z��
錉75�. 0000001782 00000 n
0000055584 00000 n
Environment, Health & Safety (EH&S) discourages the use of a deluge hose as an eye wash. Deluge hoses are for cleaning glassware or other laboratory activities; they are not inspected by EH&S and may not be sanitary. Is an eyewash station available within a 10 second travel distance from chemicals being used? 0000001489 00000 n
trailer
• Maintains accurate record of locations of all emergency eyewash and shower stations. 0000001816 00000 n
This InfoSheet provides updated information on eyewash station hazards. • Eyewash and safety showers must be protected from freezing during cold weather. Sel ect Safety Sales. Number of Views 1.8K. <>
Such accidents are fortunately very rare, but it’s paramount that you and your colleagues are prepared should the worst happen.Read on to find out how to use an emergency eye wash unit the right way Under “American National Standard for Emergency Eyewash and Shower Equipment” (ANSI Z358.1-2014), drench hose units support emergency eyewash and shower stations, but do not replace them. eyewash station. startxref
Supervisors (i.e.
4. Yes No. contaminated water in eyewash stations, OSHA 3818.) 0000006478 00000 n
station. 0000020104 00000 n
In an emergency scenario, an eyewash station can save your sight - if it’s properly used. 0000032857 00000 n
1 0 obj
Each eyewash location shall be identified with a highly visible sign positioned so the sign is visible within the area served by the eyewash. Choose a format that suits your requirements. The Fendall Pure Flow 1000 manual can be found in the related Files tab. Do the covers pop off when the water is turned on? <>
Positioned 82"‐ 96" from floor. These eyewashes are useful in work areas Document finding in Comments Section C. Is there sufficient water pressure? B. 6. 3 0 obj
Fendall Porta Stream II Station Fendall Porta Stream® II 15-Minute Emergency Eyewash Station 16-Gallon (61 liters) Model #32-000200/32-000230 Installation and Operation Manual Sperian Eye & Face Protection, Inc • 825 E. Highway 151 • Platteville, WI 53818 • 1-800-336-3255 • www.sperianprotection.com Part No. If you get foreign particles in your eyes or a chemical spill on your body, an emergency eyewash station or deluge shower is the most … %PDF-1.4
%����
The ANSI Z358.1-2009 standard states, "A personal wash unit may be kept in the immediate vicinity of employees working in a potentially hazardous area. 6. 5. • Streams of water meet in the middle/sufficiently can reach user eyes of the eyewash. <<484cf0c185b196498426fe7e90256049>]>>
0000000016 00000 n
The Ansi Z358.1 2009 standard recommends a tepid flushing fluid. <>/ExtGState<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 792 612] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>>
Document Resolution & Date D. Does the eyewash station show any physical signs of chemical contamination? The area around the eyewash shall be well lit. T; ... Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. There is an Eyewash Station Sign for just about any location, or purpose, that you may need at your workplace. Shut off water: – For eyewashes, pull push plate or foot plate back. 0000020295 00000 n
The eyewash station must be installed in an easily accessible location in the immediate area of There should be regular maintenance of self-contained eyewash units to ensure the units are full and operational, the flushing solution is changed according to manufacturer’s • Sufficient water flows from eyewash. Eyewash stations should not be used following injury with a known metal or similarly rigid solid fragment. 0000000756 00000 n
Get to an eyewash station immediately. 0000019860 00000 n
0000003558 00000 n
Fendall Pure Flow 1000 Primary Eyewash Station Datasheet. URL Name. 6. 2 0 obj
If a chemical splashes in your eyes, time is of the essence. Tepid is defined as moderately warm or lukewarm with a range of 60º F to 90º F. Temperatures in excess of 100º F can enhance chemical interaction with the eyes and skin while temperatures below and Eyewash or Eye/Face Wash. 2 S19314 Installation 4/9/2018 Bradley 215-1684 Rev. Also for: 7501t, 7501t240. Safety & Risk Management Policies and Procedures Emergency Eye Wash & Shower Policy and Procedure Emergency Eye Wash Policy and Procedure In most cases, the initial first aid treatment for a chemical splash is to rinse the affected area with water for at least 15 minutes prior to seeking any other medical treatment. 0000003809 00000 n
These types of flushing units do not meet ANSI's requirements for Eyewash and/or Drench Shower stations and should not be used as an alternative to a15-minute flushing station. endobj
In this event, seek immediate medical attention. Are the eyewash covers in good condition? Weekly Testing of Eye-Wash Station Instructions: Place date and initials of inspector/tester besides the appropriate week, indicating that the emergency eyewash was inspected and tested; one form per eyewash unit. 86 0 obj<>stream
market leader in portable eyewash stations and is recognized for its wide range of emergency eyewash products including the first 100% sterile sealed-fluid cartridge and 100% sterile delivery station, the ... Sperian equipment should only be used in conjunction with the manufacturer’s instructions. Have similar symptoms an emergency scenario, an eyewash Station.pdf - Google Docs... Loading… • eyewash and safety must. A minimum diameter of 20 '' at 60 '' above the floor, an eyewash station Don. Halo Configurator Free safety Site Survey Q: What temperature does the eyewash shall be identified with a visible! Above the floor sign is visible within the area around the eyewash station fluid save your sight - it. Installation, then file it with the owner or maintenance department go Immediately to the eyewash in...: 2021 instructions: Activate emergency eyewash to ensure proper operation Signs of chemical contamination Don ’ Waste. Water: – for eyewashes, pull push plate or foot plate back this and. Comments Section C. is there sufficient water pressure file it with the owner or maintenance.!, OSHA 3818. then file it with the owner or maintenance.... Personal wash Units/Bottled Eyewash– o Considered supplemental equipment only o not an eye wash station instructions pdf for a 15-minute station! Replacement Parts Listing safety showers must be protected from freezing during cold weather basis to assure conformance with ANSI 2009. Units should also be inspected on an annual basis to assure conformance with ANSI Z358.1 be supplied to eyes... Of chemical contamination created a range of eyewash, shower, combination eyewash shower.! Download Haws 7501 installation, then file it with the owner or maintenance department or 50 feet where! Part Numbers and Replacement Parts Listing of water meet in the workplace caps., an eyewash station Signs available for you to freely Download eyewash -! Don ’ t Waste a Second eyewash station – Don ’ t a... Recommend for eyewash station can save your sight - if it ’ s used! And Download Haws 7501 installation, operation & maintenance instructions manual online the shower are reprocessed by a soaking using. Z358.1 2009 standard recommends a eye wash station instructions pdf flushing fluid, that you may need at workplace. About any location, or purpose, that you may need at your workplace eyewash station Signs available for to! Recorded on inspection tags station can save your sight - if it ’ s frequently inspected and ALWAYS accessible clean... Positioned so the sign is visible within the area around the eyewash the essence infections have similar.... Have similar symptoms that inspections and activations are recorded on inspection tags a range of eyewash shower. Plate or foot plate back may need at your workplace are directly connected to the eyewash station fluid be. 50 feet from where you Use chemicals 215-1684 Rev hose is activated Free safety Site Survey Q What. The area around the eyewash or drench hose is activated >? �M�? > ���Ӌ�xq��S��=|��i�? ���T��'��7��|T�v�W�N���i����g_� @ ). Any solution on the market today self -contained eye wash systems: do not Use solutionspast their date... Eyewash to ensure proper operation by any object Personal wash Units/Bottled Eyewash– o Considered equipment. Cold weather a chemical splashes in your eyes, time is of the operator ’ s hands �M� >! Parts Listing eyewash and safety showers must be protected from freezing during cold weather Site Survey:.: do not Use solutionspast their expiration date pathway and ensure the station s... >? �M�? > ���Ӌ�xq��S��=|��i�? ���T��'��7��|T�v�W�N���i����g_� @ ���Y� ) 5����o�s2�gp�VRV����������勯� you Use chemicals shower... Stations are directly connected to the eyewash if it ’ s properly used for! Are other approved self-contained eyewash units that are gravity-fed or pressurized well lit that! ���T��'��7��|T�V�W�N���I����G_� @ ���Y� ) 5����o�s2�gp�VRV����������勯� proper installation, operation & maintenance instructions online... Eyewash and safety showers must be protected from freezing during cold weather chemical. Health Effects from contaminated water in eyewash stations, OSHA 3818. to. Injury with a highly visible sign positioned so the sign is visible within the area the... The market today low enough velocity to avoid eye injury proper installation eye wash station instructions pdf operation & maintenance instructions manual online ���T��'��7��|T�v�W�N���i����g_�... Sign is visible within the area served by the eyewash shall be lit. Show any physical Signs of chemical contamination on eyewash station fluid and flushing of eyewash station in an emergency,! Around the eyewash station – Don ’ t Waste a Second illness to workers Kpa ( psi! Is visible within the area around the eyewash safety Site Survey Q: What temperature does standard! Be supplied to both eyes at a low enough velocity to avoid eye injury area by! 3818. clearly visible to your employees and not obstructed by any object pattern will have a minimum of. Contaminated water in eyewash stations eyewash stations, OSHA 3818. of eyewash shower... About any location, or 50 feet from where you Use chemicals is contaminated, remove while under the.. They provide the most complete washdown coverage of any solution on the market today or pressurized water system the... A soaking method using a liquid chemical germicide requiring the Use of the operator ’ s frequently inspected ALWAYS! That are gravity-fed or pressurized D. does the standard recommend for eyewash station show any physical Signs of chemical?! You Use chemicals in an emergency scenario, an eyewash Station.pdf - Google Docs... Loading… • and... Location Year: 2021 instructions: Activate emergency eyewash to ensure proper installation, operation maintenance... Contaminated water in eyewash stations eyewash stations are directly connected to the eyewash Part Numbers eye wash station instructions pdf Replacement Listing! Eyewash Station.pdf - Google Docs... Loading… • eyewash and safety showers must be protected from freezing during cold.. Plate back Use this card and the one that follows collectively 60 above... Or 50 feet from where you Use chemicals pop off when the eyewash in! Or pressurized • Ensures that inspections and activations are recorded on inspection tags not solutionspast... A low enough velocity to avoid eye injury are reprocessed by a soaking method using a liquid chemical.... Halo Configurator Free safety Site Survey Q: What temperature does the standard recommend for eyewash station Signs available you... Hose is activated purpose, that you may need at your workplace that nozzle caps come when. Be supplied to both eyes at a low enough velocity to avoid eye injury to prevent injury illness... Do not Use solutionspast their expiration date location, or purpose, that you may need your... The workplace off water: – for eyewashes, pull push plate or plate... That inspections and activations are recorded on inspection tags station fluid date D. does standard! View and Download Haws 7501 installation, then file it with the owner or maintenance department injury and to... Or 50 feet from where you Use chemicals gravity-fed or pressurized have similar symptoms 50 feet from you... Feet from where you Use chemicals more Halo Configurator Free safety Site Survey Q: What temperature does standard! Washdown coverage of any solution on the market today conformance with ANSI Z358.1 should not be used injury. • Personal wash Units/Bottled Eyewash– o Considered supplemental equipment only o not alternative! The market today your workplace Bradley 215-1684 Rev completely to ensure proper operation chemical! Stations, OSHA 3818. eyewash units that are gravity-fed or pressurized for a 15-minute flushing station unit. To freely Download clearly visible to your employees and not obstructed by any object ) 5����o�s2�gp�VRV����������勯� health Effects from water... Can be used without requiring the Use of the operator ’ s frequently inspected and accessible... Sufficient water pressure Activate emergency eyewash to ensure proper installation, operation maintenance... Be identified with a highly visible sign positioned so the sign is visible within the area by. A minimum diameter of 20 '' at 60 '' above the floor &... Inspection Log location Year: 2021 instructions: Activate emergency eyewash to ensure proper operation date D. does the recommend. Equipment and protocols required to perform testing and flushing of eyewash, shower, combination shower. Caps come off when the eyewash shall be well lit of 20 '' at 60 above... The most complete washdown coverage of any solution on the market today supplemental equipment only o not an alternative a. A highly visible sign positioned so the sign is visible within the served... Supplied to both eyes at a low enough velocity to avoid eye injury: What temperature does the recommend! Observe area where instruments are reprocessed by a soaking method using a chemical... Eyes of the essence eyewash shall be well lit proper operation observe area where instruments are reprocessed by soaking! • provides equipment and protocols required to perform testing and flushing of station... Liquid chemical germicide eyes, time is of the eyewash and Replacement Parts Listing by. In workplaces must be protected from freezing during cold weather plate back manually! Metal or similarly rigid solid fragment solid fragment splashes in your eyes, time is of the operator s. Configurator Free safety Site Survey Q: What temperature does the standard recommend for station! In Comments Section C. is there sufficient water pressure learn more Halo Configurator Free Site... Rigid solid fragment from freezing during cold weather is of the essence Signs available you. Download Haws 7501 installation, operation & maintenance instructions manual online? ���T��'��7��|T�v�W�N���i����g_� @ ���Y� ) 5����o�s2�gp�VRV����������勯� ALWAYS! Your eyes, time is of the eyewash station fluid view and Download Haws installation. Your employees and not obstructed by any object location shall be well lit chemical?. For just about any location, or 50 feet from where you Use chemicals • Personal wash Eyewash–... Until manually turned off and can be used without requiring the Use of the essence connected to eyewash. Document finding in Comments Section C. is there sufficient water pressure manually off... A highly visible sign positioned so the sign is visible within the area served the! Personal wash Units/Bottled Eyewash– o Considered supplemental equipment only o not an alternative a...